HRC Fuselinks & Installation Accessories

SL3 Street Lighting Cut-Outs 25A, 240V AC
Designed to meet BS 7654 and includes the requirements for use by Lighting and Highway Authorities.

Single and double pole versions accept tag type fuselinks from 2A to 25A.

SL3 units are available as follows:

Live, Neutral & Separate Earth Versions:

  • Single pole with 1 fuseway (Classification, type 1).
  • Double pole with 1 fuseway (Classification, type 4).
  • Double pole with 2 fuseways (Classification, type 6).

The above are fitted with PVC grommets and are also available with SWA gland/ferrule plates.

Live & Combined Neutral / Earth Versions:

  • Single pole with 1 fuseway (Classification, type 2).
  • Single pole with 2 fuseways (Classification, type 3).

SL3 Range Features

  • Designed to meet BS 7654 and includes requirements for use by Lighting and Highway Authorities.
  • Robust construction manufactured from quality thermo-plastic injection moulded material.
  • Single & double pole versions accept tag type fuselinks from 2A to 25A.
  • Compact dimensions - a narrow width of 74mm makes units suitable for smaller columns.
  • Screw down carrier offering enhanced security.
  • Integral terminal shield shrouding both the live and neutral incoming terminals of double pole cutouts when carrier is removed.
  • Padlocking facility to obstruct the insertion of the carrier during maintenance work.
  • Integral wiring channel allows a fused spur up to 6mm² to be taken from the bottom of the units.
Cable Entry Options

PVC Grommets

SWA Gland/Ferrule Plate

Tapped Gland Plate
(Compression Glands
not supplied)
 

SL3 Cut-Outs 25A, 240V AC

Live, Neutral &
Separate Earth

BS 7654

Cut-Out

Cut-Out

Description

Classification

Configuration

Cat. No.

Single Pole
One Fuseway
with
PVC grommets

Type 1

SL3S1

Single Pole
One Fuseway
Steel Wire Armour
Version

-

SL3S1A

Double Pole
One Fuseway
with
PVC grommets

Type 4

SL3D1

Double Pole
One Fuseway
Steel Wire Armour
Version

-

SL3D1A

Double Pole
Two Fuseways
with
PVC grommets

Type 6

SL3D2

Double Pole
Two Fuseways
Steel Wire Armour
Version

-

SL3D2A
Steel wire armour versions incorporate a gland/ferrule plate
Cat. No.
SL3A

 

SL3 Cut-Outs 25A, 240V AC

Live & Combined Neutral / Earth

BS 7654

Cut-Out

Cut-Out

Description

Classification

Configuration

Cat. No.

Single Pole
One Fuseway
with
PVC grommets

Type 2

SL3S1NE

Single Pole
Two Fuseways
with
PVC grommets

Type 3

SL3S2NE

 

Cable Extension Boxes

Cable extension boxes are available in four basic configurations. Other configurations can be supplied to special order.

All extension boxes have a brass gland plate with:
1 x 20mm dia. hole
2 x 25mm dia. holes
2 x M6 earth screws & blank plugs.

Note: An alternative gland plate with 3 x 25mm dia. holes is available, Cat. No. SL3BG

 

Cable Extension Boxes

Description

Configuration

Cat. No.

Extension box without terminals for increased cabling space

SL3B

Extension box with two main incoming (looping) terminals at opposite sides of the box, leaving the throat clear

SL3B2*

Extension box with four terminals: two twin incoming (looping) terminals two twin incoming, single outgoing terminals

SL3B4*

Extension box with four lug type M6 terminals
the two central terminals incorporate a single ongoing tunnel terminal

SL3B4L*
* With the addition of auxiliary terminal SL3BAT an ongoing terminal can be added to either or both the terminals positioned at the side of the extension box.
 

Cut-Out and Extension Box Terminal Capacities

Terminals

Min. to Max. Circular Stranded
Copper Conductors

SL3 cut-out
single outgoing terminals

1.5mm² up to 16mm²

SL3 cut-out
twin incoming terminals

1.5mm² up to 25mm²

Extension box
standard terminals

1.5mm² up to 25mm²
(25mm² shaped stranded)

Extension box
lug type terminals

M6

Auxiliary
terminals

1.5mm² up to 10mm²

Accessories

Gland Plate Accessories for Cut-Outs

Description

Accessory

Cat. No.

Steel wire armour gland/ferrule plate to convert standard cut-outs to an SWA incomer arrangement, cables must be less than 18mm dia. under the armour

SL3A

Tapped plate suitable for two 20mm dia. compression glands
(not supplied)

SL3G

PVC cap for an unused way in an SL3 gland plate

SL3AC

M20 plug for an unused way in SL3G gland plate

SL3GP
 

Accessories for Extension Boxes

Description

Accessory

Cat. No.

Auxiliary terminal 10mm²

SL3BAT

Alternative gland plate with
3 x 25mm holes

SL3BG

20mm dia. blanking plug
for gland plates

SL3P20

25mm dia. blanking plug
for gland plates

SL3P25
 

Spare Fuse Carriers

Carrier Description

Suitable for Cut-Outs

Cat. No.

Single pole one fuse

SL3S1, SL3S1A, SL3S1NE

SL3S1C

Single pole two fuses

SSL3S2NE

SL3S2C

Double pole one fuse

SL3D1, SL3D1A

SL3D1C

Double pole two fuses

SL3D2, SL3D2A

SL3D2C
 

HRC Fuselinks

Rating

Cat. No.

2A

BLST2

4A

BLST4

6A

BLST6

10A

BLST10

15A

BLST16

20A

BLST20

25A

BLST25

32A

BLST32
 

Dimensions (mm)

Standard Gland Plate
Diameter ØA = 20mm
Diameter ØB = 25mm

Alternative SL3BG Gland Plate
Diameter ØA = 25mm
Diameter ØB = 25mm

Top | Home | E-mail